Sunday May 20

Fixed Air Amplifiers - Technical Information


Air Amplifiers Specifications

Air amplifiers come in five standard outlet (outside) diameters:
  • 3/4" (19mm)
  • 1-1/4" (31mm)
  • 2" (51mm)
  • 4" (101mm)
  • 8" (200mm)
Air amplifiers come with a standard .002" (.05mm) shim to control the compressed air exit gap which will work for 90% of all applications encountered. If greater force is required, more .002" (.05mm) shims or a .003" (.07mm) shim may be installed to open the gap for greater flow.

Air Amplifiers - Ratios (approx.)
  • Model AM10: 6.5:1
  • Model AM20: 14:1
  • Model AM40: 15:1
  • Model AM75: 15:1
  • Model AM125: 16:1
air_amplifiers_dimensions

Model Number
Outside Diameter
Of Outlet
*A
B
C
D
E
F
G
H
I
J
K*
(NPT)
AM10
3/4"
0.39
1.30
0.98
1.77
2.28
0.20
0.16
0.59
0.73
1.55
1/8"
AM20
1-1/4"
0.79
1.85
1.50
2.40
3.03
0.27
0.20
0.59
1.22
2.16
1/4"
AM40
2"
1.57
3.15
2.95
3.58
4.13
0.27
0.27
0.78
2.00
2.91
3/8"
AM75
4"
2.95
5.90
4.91
6.89
8.46
0.53
0.55
1.19
3.97
5.90
1/2"
AM125
8"
4.92
10.39
7.08
-
-
-
-
0.79
7.79
16.73
3/4"
* BSP Adapters Supplied Upon Request Free Of Charge

Model Number
Outside Diameter
Of Outlet
*A
B
C
D
E
F
G
H
I
J
K*
(NPT)
AM10
19mm
10
33
25
45
58
5
4
15
19
40
1/8"
AM20
31mm
20
47
38
61
77
7
5
15
31
55
1/4"
AM40
51mm
40
80
75
91
105
7
7
20
51
74
3/8"
AM75
101mm
75
150
125
175
215
13
4
30
101
150
1/2"
AM125
200mm
125
264
180
-
-
-
-
20
200
425
3/4"
* BSP Adapters Supplied Upon Request Free Of Charge

Models


air_movers_model_am10
Model - AM10

air_movers_model_am20sModel - AM20

air_movers_model_am40Model - AM40

air_movers_model_am75Model - AM75

air_movers_model_am125Model - AM125

Air Mover Air Amplifier - Compressed Air Consumption

(Based on gap of 0.002” (.05mm)
Compressed Air Consumption in SCFM (SLPM)

Inlet Pressure
AM10
AM20
AM40
AM75
AM125
20 PSIG
(1.4 BAR)
2.2
(62.3)
4.3
(121.8)
8.0
(226.5)
16.5
(467.2)
65.0
(1840.6)
40 PSIG
(2.8 BAR)
3.4
(96.3)
6.1
(172.7)
11.3
(320.0)
23.2
(657.0)
90.0
(2548.5)
60 PSIG
(4.1 BAR)
4.3
(121.8)
7.5
(212.4)
15.0
(424.8)
29.7
(841.0)
119.5
(3383.9)
80 PSIG
(5.5 BAR)
4.9
(138.8)
9.3
(263.3)
19.3
(546.5)
37.0
(1047.7)
137.5
(3893.6)
100 PSIG
(6.9 BAR)
5.8
(164.2)
11.0
(311.5)
25.1
(710.8)
44.0
(1245.9)
150.0
(4247.5)
120 PSIG
(8.4 BAR)
6.1
(172.7)
11.8
(334.1)
26.0
(736.2)
47.0
(1330.9)
152.0
(4304.2)

Air Mover Air Amplifier - Ducting

Both the inlet (vacuum intake) and discharge ends of the unit may be ducted for light material and fume conveying applications. Care must be taken to avoid unnecessary restrictions that will cause back pressure or suction resistance that will reduce performance levels. Keep back pressure and resistance to under 2" of water column.

Downloads

pdf_edit Air Amplifier
pdf_edit Maintenance & Installation